Complete, Convertible, Innovative

CONCEPT
DIFFERENT NEEDS,
A UNIQUE AND COMPLETE SYSTEM

Building on its success in the hip, knee and spine product areas, Medacta International is expanding into the shoulder arthroplasty market.

With the Medacta Shoulder System, we are entering the fast growing upper extremity market with the same patient-centric vision and ambition that characterized our growth and success in knee, hip and spine technology: delivering innovation through high-level surgical education and providing real benefits to patients and healthcare system sustainability” said Alberto Siccardi, President and Founder of Medacta International.


 

The Medacta Shoulder System is a modular solution that features a broad range of options, including wide-ranging sizes, adjustable offset and innovative configurations both in the anatomic and in the reverse configuration.
The Medacta Shoulder System provides 2 stem options, standard and short, 3 humeral inclination options for TSA (128 º /135 º /142º) and 2 for RSA (145° and 155°), 4 sizes for RSA glenosphere and 10 cemented pegged glenoid for TSA for an optimized mismatch.

Designed by a group of expert surgeons from Europe, Australia and the United States, the Medacta Shoulder System offers the flexibility to move from a total to a reverse arthroplasty, without the need to revise the all components. The aim is to have conversions rather than revisions of the all prosthesis components.

The Medacta Shoulder System is composed of innovative components, the design of which has been based on the most recent research in shoulder replacement. The Medacta Shoulder System is compatible with, and can be further enhanced by, the CT-based MyShoulder 3D preoperative planning solution, offering patient-specific humeral and glenoid guides. 
 
 
ANATOMIC

HUMERAL DIAPHYSIS

Standard and Short versions
11 sizes for each version
Cementless (Ti-Plasma spray + HA) and cemented (only for Standard Stem) options

HUMERAL ANATOMIC METAPHYSIS

3 inclination options: 128 º /135 º /142º
Cementless (Ti-Plasma spray + HA) and cemented options
Suture Sleeves: Ø2.5mm

DOUBLE ECCENTER

Adjustable head eccentricity (0 ÷ 5 mm)

HUMERAL HEAD

10 sizes
Material: CoCrMo - ISO 5832-12 (ASTM F1537)

CEMENTED GLENOID

10 sizes
Material: Highly cross-linked polyethylene

REVERSE

HUMERAL DIAPHYSIS

Standard and Short versions
11 sizes for each version
Cementless (Ti-Plasma spray + HA) and cemented (only for Standard Stem) options

HUMERAL REVERSE METAPHYSIS

Two height options: +0 and +9 mm
Two version options: +/- 20º
Material: Ti6Al4V - ISO 5832-3 (ASTM F136)
Inlay design with HA
Suture Sleeves: Ø2 mm

HUMERAL REVERSE HC LINER

Three height options: +0 / +3 / +6 mm
Inclination options: 145° and 155°
Material: Highly cross-linked polyethylene

PEGGED GLENOID BASEPLATE

Three diameter options: 22, 24.5 and 27 mm
Three peg length options: 15, 25 and 35 mm
Material: Ti6Al4V - ISO 5832-3 (ASTM F136) with HA (Grit blasted front surface)

THREADED GLENOID BASEPLATE

Two diameter options: 24.5 and 27 mm
Three peg length options: 25, 30 and 35 mm
Material: Ti6Al4V - ISO 5832-3 (ASTM F136) + Type II anodization with 300μm Mectagrip

GLENOSPHERE

Four diameter options: 32, 36, 39 and 42 mm
Lateralized COR: 4mm
Embedded Inferior offset: 2mm
Material: CoCrMo - ISO 5832-12 (ASTM F1537)

GLENOID POLYAXIAL LOCKING SCREW

10 sizes
± 15° of angulation
Material:

  • Outer screw: Ti6Al4V - ISO 5832-3 (ASTM F136) + Type II anodization
  • Inner screw: CoCrMo - ISO 5832-12 (ASTM F1537)

GLENOID POLYAXIAL NON-LOCKING SCREW

10 sizes
± 15° of angulation
Material: Ti6Al4V - ISO 5832-3 (ASTM F136) + Type II anodization

TECHNICAL DATA

HUMERAL STABILITY

The humeral diaphysis has a self-centering and self-orienting shape. The calcar design has been optimize, through extensive trialing using 3D imaging and cadaver analysis, and delivers enhanced primary stability. Achieving a precise fit between stem and humeral canal is made possible with the extensive size range available with this system.

REVERSE CONFIGURATION IMPROVEMENTS

With an innovative design of the liner, the surgeon has the opportunity to adapt the system to the patient's conditions by potentially increasing joint ROM (145° humeral inclination) and maximizing joint stability (155° humeral inclination). The glenosphere has a lateral offset (4 mm) and also an inferior offset (2 mm) to reduce the risk of scapular notching. The complete hemispherical design delivers stability through full ROM.

ANATOMIC CONFIGURATION IMPROVEMENTS

The surgeon has the opportunity to ideally match and reproduce the head-stem offset using the double eccenter-head. This option delivers an adjustable head eccentricity between 0 and 5 mm. The Medacta Shoulder System provides 3 anatomical metaphysis inclination options (128° / 135° / 142°) to match the pre-operative humeral inclination.

IDEAL PLATFORM FOR CONVERSION FROM TSA TO RSA

In case of revision, the humeral diaphysis remains in place and is used to receive the reverse metaphysis and the reverse liner. This is a less invasive revision surgery option but continues to deliver satisfactory stability of the prosthesis.

SYNERGY

MYSHOULDER

MyShoulder is a patient-specific instrumentation, allowing the surgeon to realize his pre-operative 3D planning, based on CT images of the patient’s shoulder. The pre-operative 3D planning allows to manufacture an humeral resection guide and a glenoid positioning guide.
This innovative concept combines different features giving potential benefits to both the surgeon and to the patient.